维普中文期刊产品整合服务
3篇 您的检索式:作者名="Yanyue Gu"
    题名 作者 年代 出处 被引量
1Prospect of China's ambient air quality standards显示文摘Ambient air quality standards are the core strategic goal of ambient air quality management.Countries worldwide have given importance to research on the development of ambient air quality standards.To understand the history of the development of China’s ambient air quality standards,this study analyzed the background associated with all previous formulations and revisions of the standards,classification of functional areas,standard grading,pollutants,and evolution of the standard limits over the past 40 years.The results show that since the initial release of the“Ambient Air Quality Standard”by China in 1982,it has been supplemented once,revised twice,and modified twice.The first ambient air quality standard specified the standard limits of six pollutants commonly found in ambient air.With the development of ambient air quality management,the number of pollutants has increased to ten.Since the release of the“Ambient Air Quality Standards”in 2012,the ambient air quality in China has significantly improved.However,the proportion of cities meeting these standards is still low.At present,China is suitably positioned to make the standards associated with 24 hr SO2concentrations more stringent such that it meets the values defined in the World Health Organization(WHO)interim target-2 and the WHO air quality guideline(AQG).We further suggested that the SO2standard should be revised promptly.Simultaneously,regions with a relatively high proportion of cities meeting the standard are encouraged to introduce more stringent interim target limits in due course to manage the local ambient air quality.Zongshuang Wang Yufei Tan Min Guo Miaomiao Cheng Yanyue Gu Siyu Chen Xuefang Wu Fahe Chai 2023Journal of Environmental Sciences2023,,1:2
2Design of front-end electronics based on a programmable transimpedance amplifier for an HIAF beam intensity detector显示文摘Background The beam intensity of the High Intensity Heavy-ion Accelerator Facility(HIAF)is converted into current sig-nals by beam intensity detectors and then processed by front-end electronics.The performance of the front-end electronics affects the measurement accuracy of the accelerator.Purpose To design front-end electronics to readout the current signals from a beam intensity detector.Methods A programmable transimpedance amplifier(TIA)converts current signals into voltage signals and amplify the signals.An analog-to-digital converter(ADC)converts analog signals into digital signals under the control of ZYNQ7015.Results and conclusion An integrated front-end electronics system was designed and verified.The electronics could collect and process current signals from 40 pA to 4 mA.The system had a higher dynamic range than traditional beam intensity measuring electronics.Xiangyu Qiu Yanyu Wang Zhixue Li Fafu Ni Ruixia Tian Yuan Wei Kewei Gu Xuejing Hu 2021Radiation Detection Technology and Methods2021,5,3:0
3Experimental Preparation for Searching New Nuclide ^(69)Kr显示文摘Experimental Preparation for Searching New Nuclide ^(69)KrExperimentalPreparationforSearchingNewNuclide^(69)Kr¥XuXiaoji;MaRuic...Xu Xiaoji Ma Ruichang Huang Wencue Gu Zhongdao Wang Wei Yin Shuzhi and Wang Yanyu 1995IMP & HIRFL Annual Report1995,,0:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费