维普中文期刊产品整合服务
11篇 您的检索式:作者名="Sang Shengbo"
    题名 作者 年代 出处 被引量
1In situ fabrication of organic electrochemical transistors on a microfluidic chip显示文摘Microfluid chips integrating with organic electrochemical transistors (OECTs) are useful for manufacturing biosensors with high throughput and large-scale analyses. We report here the utilization of alternating current (AC) electrodeposition to fabricate OECTs in situ on a microfiuid chip. With this method, the organic semiconductor (OS) layer with a channel length of 8μm was readily prepared without requiring the postbonding process in the conventional construction of microfluidic chips. Poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate)/graphene quantum dots (PEDOT:PSS/GQDs) composites with different morphologies, such as microfilms, nanodendrites and nanowires were electropolymerized. The mass transfer process of the electropolymerization reaction was evidenced to be diffusion limited. Morphologies, growth directions, and chemical structures of OS layers could be tuned by the amplitude and the frequency of the AC voltage. Transfer and output characteristic curves of OECTs were measured on the microfluidic chip. The maximum transconductance, on/off current ratio and threshold voltage measured in the experiment was 1.58 mS, 246, and 0.120 V, respectively.Jianlong Ji Mangmang Li Zhaowei Chen Hongwang Wang Xiaoning Jiang Kai Zhuo Ying Liu Xing Yang Zhen Gu Shengbo Sang Yang Shu 2019Nano Research2019,12,8:3
2Biocompatible chitosan/polyethylene glycol/multi-walled carbon nanotube composite scaffolds for neural tissue engineering显示文摘Carbon nanotube(CNT)composite materials are very attractive for use in neural tissue engineering and biosensor coatings.CNT scaffolds are excellent mimics of extracellular matrix due to their hydrophilicity,viscosity,and biocompatibility.CNTs can also impart conductivity to other insulating materials improve mechanical stability guide neuronal cell behavior and trigger axon regeneration.The performance of chitosan(CS)/polyethylene glycol(PEG)composite scaffolds could be optimized by introducing multi-walled CNTs(MWCNTs).CS/PEG/CNT composite scaffolds with CNT content of 1%,3%,and 5%(1%=0.01 g/mL)were prepared by freeze-drying.Their physical and chemical properties and biocompatibility were evaluated.Scanning electron microscopy(SEM)showed that the composite scaffolds had a highly connected porous structure.Transmission electron microscope(TEM)and Raman spectroscopy proved that the CNTs were well dispersed in the CS/PEG matrix and combined with the CS/PEG nanofiber bundles.MWCNTs enhanced the elastic modulus of the scaffold.The porosity of the scaffolds ranged from 83%to 96%.They reached a stable water swelling state within 24 h,and swelling decreased with increasing MWCNT concentration.The electrical conductivity and cell adhesion rate of the scaffolds increased with increasing MWCNT content.Immunofluorescence showed that rat pheochromocytoma(PC12)cells grown in the scaffolds had characteristics similar to nerve cells.We measured changes in the expression of nerve cell markers by quantitative real-time polymerase chain reaction(qRT-PCR),and found that PC12 cells cultured in the scaffolds expressed growth-associated protein 43(GAP43),nerve growth factor receptor(NGFR),and class IIIβ-tubulin(TUBB3)proteins.Preliminary research showed that the prepared CS/PEG/CNT scaffold has good biocompatibility and can be further applied to neural tissue engineering research.Shengbo SANG Rong CHENG Yanyan CAO Yayun YAN Zhizhong SHEN Yajing ZHAO Yanqing HAN 2022Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)2022,23,1:2
3Mesenchymal stem cells loaded on 3D-printed gradient poly(e-caprolactone)/methacrylated alginate composite scaffolds for cartilage tissue engineering显示文摘Cartilage has limited self-repair ability due to its avascular,alymphatic and aneural features.The combination of three-dimensional(3D)printing and tissue engineering provides an up-and-coming approach to address this issue.Here,we designed and fabricated a tri-layered(superficial layer(SL),middle layer(ML)and deep layer(DL))stratified scaffold,inspired by the architecture of collagen fibers in native cartilage tissue.The scaffold was composed of 3D printed depth-dependent gradient poly(e-caprolactone)(PCL)impregnated with methacrylated alginate(ALMA),and its morphological analysis and mechanical properties were tested.To prove the feasibility of the composite scaffolds for cartilage regeneration,the viability,proliferation,collagen deposition and chondrogenic differentiation of embedded rat bone marrow mesenchymal stem cells(BMSCs)in the scaffolds were assessed by Live/dead assay,CCK-8,DNA content,cell morphology,immunofluorescence and real-time reverse transcription polymerase chain reaction.BMSCs-loaded gradient PCL/ALMA scaffolds showed excellent cell survival,cell proliferation,cell morphology,collagen II deposition and hopeful chondrogenic differentiation compared with three individual-layer scaffolds.Hence,our study demonstrates the potential use of the gradient PCL/ALMA construct for enhanced cartilage tissue engineering.Yanyan Cao Peng Cheng Shengbo Sang Chuan Xiang Yang An Xiaochun Wei Zhizhong Shen Yixia Zhang Pengcui Li 2021Regenerative Biomaterials2021,8,3:2
4Raman quantitate stress in nano-thin film of MEMS显示文摘Sang Shengbo Xue Chengyang Zhang Wendong 2007Solid State Phenomena2007,123,:1
5A novel PDMS micro membrane biosensor based on the analysis of surface stress 显示文摘Sang Shengbo Witte Hartmut 2010Biosensors and Bioelectronics2010,25,11:1
6Surface Stress- Based Biosensors 显示文摘Sang Shengbo Zhao Yuan Zhang Wendong 2014Biosensors and Bioeleetronies2014,,51:1
7Bearing Fault Diagnosis with DDCNN Based on Intelligent Feature Fusion Strategy in Strong Noise显示文摘Intelligent fault diagnosis in modern mechanical equipment maintenance is increasingly adopting deep learning technology.However,conventional bearing fault diagnosis models often suffer from low accuracy and unstable performance in noisy environments due to their reliance on a single input data.Therefore,this paper proposes a dual-channel convolutional neural network(DDCNN)model that leverages dual data inputs.The DDCNN model introduces two key improvements.Firstly,one of the channels substitutes its convolution with a larger kernel,simplifying the structure while addressing the lack of global information and shallow features.Secondly,the feature layer combines data from different sensors based on their primary and secondary importance,extracting details through small kernel convolution for primary data and obtaining global information through large kernel convolution for secondary data.Extensive experiments conducted on two-bearing fault datasets demonstrate the superiority of the two-channel convolution model,exhibiting high accuracy and robustness even in strong noise environments.Notably,it achieved an impressive 98.84%accuracy at a Signal to Noise Ratio(SNR)of−4 dB,outperforming other advanced convolutional models.Chaoqian He Runfang Hao Kun Yang Zhongyun Yuan Shengbo Sang Xiaorui Wang 2023Computers, Materials & Continua2023,77,12:0
83D bioprinting of in vitro porous hepatoma models:establishment,evaluation,and anticancer drug testing显示文摘Traditional tumor models do not tend to accurately simulate tumor growth in vitro or enable personalized treatment and are particularly unable to discover more beneficial targeted drugs.To address this,this study describes the use of threedimensional(3D)bioprinting technology to construct a 3D model with human hepatocarcinoma SMMC-7721 cells(3DP-7721)by combining gelatin methacrylate(GelMA)and poly(ethylene oxide)(PEO)as two immiscible aqueous phases to form a bioink and innovatively applying fluorescent carbon quantum dots for long-term tracking of cells.The GelMA(10%,mass fraction)and PEO(1.6%,mass fraction)hydrogel with 3:1 volume ratio offered distinct pore-forming characteristics,satisfactorymechanical properties,and biocompatibility for the creation of the 3DP-7721 model.Immunofluorescence analysis and quantitative real-time fluorescence polymerase chain reaction(PCR)were used to evaluate the biological properties of the model.Compared with the two-dimensional culture cell model(2D-7721)and the 3D mixed culture cell model(3DM-7721),3DP-7721 significantly improved the proliferation of cells and expression of tumor-related proteins and genes.Moreover,we evaluated the differences between the three culture models and the effectiveness of antitumor drugs in the three models and discovered that the efficacy of antitumor drugs varied because of significant differences in resistance proteins and genes between the three models.In addition,the comparison of tumor formation in the three models found that the cells cultured by the 3DP-7721 model had strong tumorigenicity in nude mice.Immunohistochemical evaluation of the levels of biochemical indicators related to the formation of solid tumors showed that the 3DP-7721 model group exhibited pathological characteristics of malignant tumors,the generated solid tumors were similar to actual tumors,and the deterioration was higher.This research therefore acts as a foundation for the application of 3DP-7721 models in drug development research.Xiaoyuan Wang Zixian Liu Qianqian Duan Boye Zhang Yanyan Cao Zhizhong Shen Meng Li Yanfeng Xi Jianming Wang Shengbo Sang 2024Bio-Design and Manufacturing2024,7,2:0
9Pulse electrochemical synaptic transistor for supersensitive and ultrafast biosensors显示文摘High sensitivity and fast response are the figures of merit for benchmarking commercial sensors.Due to the advantages of intrinsic signal amplification,bionic ability,and mechanical flexibility,electrochemical transistors(ECTs)have recently gained increasing popularity in constructing various sensors.In the current work,we have proposed a pulse-driven synaptic ECT for supersensitive and ultrafast biosensors.By pulsing the presynaptic input(drain bias,VD)and setting the modulation potential(gate bias)near transconductance intersection(VG,i),the synaptic ECT-based pH sensor can achieve a record high sensitivity up to 124 mV pH^(-1)(almost twice the Nernstian limit,59.2 mV pH^(-1))and an ultrafast response time as low as 8.75 ms(7169 times faster than the potentiostatic sensors,62.73 s).The proposed synaptic sensing strategy can effectively eliminate the transconductance fluctuation issue during the calibration process of the pH sensor and significantly reduce power consumption.Besides,the most sensitive working point at VG,i has been elaborately figured out through a series of detailed mathematical derivations,which is of great significance to provide higher sensitivity with quasi-nonfluctuating amplification capability.The proposed electrochemical synaptic transistor paired with an optimized operating gate offers a new paradigm for standardizing and commercializing high-performance biosensors.Jianlong Ji Zhenxing Wang Fan Zhang Bin Wang Yan Niu Xiaoning Jiang Zeng-ying Qiao Tian-ling Ren Wendong Zhang Shengbo Sang Zhengdong Cheng Qijun Sun 2023InfoMat2023,5,11:0
10Effects of incident energy and angle on carbon cluster ions implantation on silicon substrate:a molecular dynamics study显示文摘Carbon cluster ion implantation is an important technique in fabricating functional devices at micro/nanoscale. In this work, a numerical model is constructed for implantation and implemented with a cuttingedge molecular dynamics method. A series of simulations with varying incident energies and incident angles is performed for incidence on silicon substrate and correlated effects are compared in detail. Meanwhile, the behavior of the cluster during implantation is also examined under elevated temperatures. By mapping the nanoscopic morphology with variable parameters, numerical formalism is proposed to explain the different impacts on phrase transition and surface pattern formation. Particularly, implantation efficiency(IE) is computed and further used to evaluate the performance of the overall process. The calculated results could be properly adopted as the theoretical basis for designing nano-structures and adjusting devices' properties.Ye Wei Shengbo Sang Bing Zhou Xiao Deng Jing Chai Jianlong Ji Yang Ge Yuanliang Huo Wendong Zhang 2017Journal of Semiconductors2017,38,9:0
11Piezoresistive properties of resonant tunneling diodes显示文摘measurement system was designed and established to test the piezoresistive properties of resonant tunneling diodes(RTDs).The current-voltage characteristic shifts of RTD at different stress states were detected.The experimental results demonstrate that the piezoresistive sensitivity of RTD is larger than 1x10−8 Pa−1.To accurately represent the piezoresistive properties of RTD,the current-voltage characteristic coherence of the same RTD was tested.According to the experimental results,the largest relative resistance shift of an RTD in the same measurement environment is less than 3%,of which 1%is caused by the testing apparatuses.MAO Haiyang XIONG Jijun ZHANG Wendong XUE Chenyang SANG Shengbo BAO Aida 2007Frontiers of Electrical and Electronic Engineering in China2007,2,4:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费