|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Transplantation of placenta-derived mesenchymal stem cells reduces hypoxic-ischemic brain damage in rats by ameliorating the inflammatory response显示文摘Hypoxic-ischemic brain damage(HIBD)is a common cause of infant death.The purpose of our research was to explore the immunoregulatory mechanism of placenta-derived mesenchymal stem cells(PD-MSCs)in HIBD treatment.Seven-day-old rat pups were randomly divided into HIBD,PD-MSC,fibroblast,and control groups.Forty-eight hours after HIBD induction,cells at a density of 5×104 cells/10µl were injected into the cerebral tissue in the PD-MSC and fibroblast groups.The TNF-α,interleukin-17(IL-17),interferon-γ(IFN-γ),and IL-10 levels were detected through quantitative real-time polymerase chain reaction(RT-PCR)and enzyme-linked immunosorbent assay(ELISA).Regulatory T cell(Tregs)populations were detected through flow cytometry,and forkhead box P3(Foxp3)was measured through western blot analysis.Behavioral tests and gross and pathological examinations showed that PD-MSC treatment exerted significantly stronger neuroprotective effects than the other treatments.The expression levels of pro-inflammatory cytokines were substantially upregulated after HI injury.Compared with fibroblast treatment,PD-MSC treatment inhibited the production of pro-inflammatory cytokines and increased the production of IL-10 in the ischemic hemispheres and peripheral blood serum(all P<0.01).Flow cytometry results showed a notable increase in the number of Tregs within the spleen of the HIBD group.Moreover,the number of Tregs and the Foxp3 expression levels were higher in the PD-MSC treatment group than in the HIBD and fibroblast groups(all P<0.01).Our research suggests that the mechanism of PD-MSC treatment for HIBD partially involves inflammatory response suppression. | Hongfang Ding Hui Zhang Huifang Ding Dong Li Xinhao Yi Xiaoxu Ma Ruijuan Li Mei Huang Xiuli Ju | 2017 | Cellular & Molecular Immunology2017,14,8: | 10 |
| 2 | Arc erosion behavior of a nanocomposite W-Cu electrical contact material显示文摘在弧故障下面的 nanocomposite W-Cu 材料的侵蚀行为被调查。材料的弧侵蚀率被决定,并且侵蚀的表面和弧侵蚀机制被扫描电子显微镜学学习。thenanocomposite W-Cu 电的接触物质显示出散布弧的一个特征,这被结束。商业地使用的 W-Cu 合金的弧故障在一些区域,和它的平均的弧侵蚀率被限制象前者的一样两次大。而且, nanocomposite W-Cu 材料的弧扑灭能力和弧稳定性是优秀的,这也被证明,并且融化是在弧的 make-and-break 操作的主要失败形式。 | CHEN Wenge KANG Zhanying SHEN Hongfang DING Bingjun | 2006 | Rare Metals2006,25,1: | 6 |
| 3 | Celastrol suppresses colorectal cancer via covalent targeting peroxiredoxin 1显示文摘As a terpenoids natural product isolated from the plant Thunder God Vine,Celastrol is widely studied for its pharmacological activities,including anti-tumor activities.The clinical application of Celastrol is strictly limited due to its severe side effects,whereas previously revealed targets and mechanism of Celastrol seldom reduce its in vivo toxicity via structural optimization.Target identification has a far-reaching influence on the development of innovative drugs,and omics data has been widely used for unbiased target prediction.However,it is difficult to enrich target of specific phenotype from thousands of genes or proteins,especially for natural products with broad promising activities.Here,we developed a text-mining-based web-server tool to enrich targets from omics data of inquired compounds.Then peroxiredoxin 1(PRDX1)was identified as the ROS-manipulating target protein of Celastrol in colorectal cancer.Our solved high-resolution crystal structure revealed the unique covalent binding mode of Celastrol with PRDX1.New derivative compound 19-048 with improved potency against PRDX1 and selectivity towards PRDX2~PRDX6 were synthesized based on crystal structure analysis.Both Celastrol and 19-048 effectively suppressed the proliferation of colorectal cancer cells.The anti-tumor efficacy of Celastrol and 19-048 was significantly diminished on xenograft nude mice bearing PRDX1 knock-down colorectal cancer cells.Several downstream genes of p53 signaling pathway were dramatically up-regulated with Celastrol or 19-048 treatment.Our findings reveal that the side effects of Celastrol could be reduced via structural modification,and PRDX1 inhibition is promising for the treatment of colorectal cancer. | Heng Xu Hongfang Zhao Chunyong Ding Defang Jiang Zijie Zhao Yang Li Xiaoyu Ding Jing Gao Hu Zhou Cheng Luo Guoqiang Chen Ao Zhang Ying Xu Hao Zhang | 2023 | Signal Transduction and Targeted Therapy2023,8,3: | 3 |
| 4 | Fluorescence enhancement of europium complex co-doped with terbium complex in a poly(methyl methacrylate) matrix 显示文摘 | Jiu Hongfang Ding Jianjun Sun Youyi | 2006 | Journal of Non-Crystalline Solids2006,352,3: | 1 |
| 5 | The precision and agreement of corneal thickness and keratometry measurements with SS-OCT versus Scheimpflug imaging显示文摘Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regions in children.Methods:Pachymetric and keratometric maps for both systems were evaluated.Central,midperipheral and peripheral corneal thickness(CT),keratometry and astigmatism power vectors were recorded.The three outcomes yielded by the same observer were used to assess intraobserver repeatability.The differences in the mean values provided by each observer were used to evaluate interobserver reproducibility.Within-subject standard deviation,test-retest repeatability(TRT)and coefficient of variation(CoV)were used to analyze the intraobserver repeatability and interobserver reproducibility.Paired T-test and Bland-Altman were used to appraise interdevice agreement.Results:Seventy-eight eyes of 78 children were included.The CoV was≤2.12 and 1.10%,respectively,for repeatability and reproducibility.TRT and CoV were lower for central and paracentral CT measurements than for peripheral measurements.The SS-OCT device generated higher precision when acquiring CT data,whereas Scheimpflug system showed higher reliability when measuring corneal keratometry.Although the CT readings measured using SS-OCT were significantly thinner than Scheimpflug device(P<0.001),the central and thinnest CT values were still of high agreement.The interdevice agreement of keratometry measurement was high for the central corneal region and moderate for the paracentral and peripheral areas.Conclusions:The precision of CT measurements by SS-OCT was higher,while the reliability of keratometry measurements by the Scheimpflug system was higher in children.Apart from the measured values in the central corneal region,the thickness and keratometry readings should not be considered interchangeable between the two systems. | Yune Zhao Ding Chen Giacomo Savini Qing Wang Hongfang Zhang Yili Jin Benhao Song Rui Ning Jinhai Huang Chenyang Mei | 2020 | Eye and Vision2020,7,1: | 1 |
| 6 | Applications of combinatorial approach to the investigation of optical functional materials显示文摘Recent applications of combinatorial methodology to the investigation of optical functional materials are reviewed on the basis of the authors' work. The content includes: basic concepts of combinatorial materials science, combinatorial investigations of UV/VUV excited photoluminescence, luminescent rear earth complex doped polymer and magneto-optical materials. The fundamental synthesis tech-niques and characterization methods in combinatorial methodology are also illustrated in the text. | LUO ZhenLin BAO Jun DING JianJun CHEN Lei LI XueFei JIU HongFang ZHANG QiJin CHAN TingShan LIU RuXi GAO Chen | 2009 | Chinese Science Bulletin2009,54,11: | 0 |
| 7 | The precision and agreement of corneal thickness and keratometry measurements with SS-OCT versus Scheimpflug imaging显示文摘Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regions in children.Methods:Pachymetric and keratometric maps for both systems were evaluated.Central,midperipheral and peripheral corneal thickness(CT),keratometry and astigmatism power vectors were recorded.The three outcomes yielded by the same observer were used to assess intraobserver repeatability.The differences in the mean values provided by each observer were used to evaluate interobserver reproducibility.Within-subject standard deviation,test-retest repeatability(TRT)and coefficient of variation(CoV)were used to analyze the intraobserver repeatability and interobserver reproducibility.Paired T-test and Bland-Altman were used to appraise interdevice agreement.Results:Seventy-eight eyes of 78 children were included.The CoV was≤2.12 and 1.10%,respectively,for repeatability and reproducibility.TRT and CoV were lower for central and paracentral CT measurements than for peripheral measurements.The SS-OCT device generated higher precision when acquiring CT data,whereas Scheimpflug system showed higher reliability when measuring corneal keratometry.Although the CT readings measured using SS-OCT were significantly thinner than Scheimpflug device(P<0.001),the central and thinnest CT values were still of high agreement.The interdevice agreement of keratometry measurement was high for the central corneal region and moderate for the paracentral and peripheral areas.Conclusions:The precision of CT measurements by SS-OCT was higher,while the reliability of keratometry measurements by the Scheimpflug system was higher in children.Apart from the measured values in the central corneal region,the thickness and keratometry readings should not be considered interchangeable between the two systems. | Yune Zhao Ding Chen Giacomo Savini Qing Wang Hongfang Zhang Yili Jin Benhao Song Rui Ning Jinhai Huang Chenyang Mei | 2022 | Eye and Vision2022,8,5: | 0 |
| 8 | Carbon nitride with encapsulated nickel for semi-hydrogenation of acetylene: pyridinic nitrogen is responsible for hydrogen dissociative adsorption显示文摘A new mechanism of catalyst has been demonstrated in this article. With the interaction between carbon nitride(CN) and encapsulated nickel, the CN in the catalyst has been endowed with new active sites for the adsorption and activation of hydrogen while nickel itself is physically isolated from the contact with reactive molecules. For the selective hydrogenation of acetylene in large amount of ethylene, the catalyst shows excellent ethylene selectivity than the nickel catalyst itself, which is almost totally unselective. Meanwhile, the CN itself is inactive for the reaction. The results of characterization demonstrate that pyridinic nitrogen doped in the carbon matrix should be the active sites for hydrogen dissociative adsorption. The theoretical calculations further confirm the results and provide with the detail in the electron transfer between nickel and CN in the catalyst. The current results supply a new concept for design of high performance catalyst. | Teng Fu Tao Wang Hongfang Sun Yida Xu Zhen Dong Xiangke Guo Luming Peng Yan Zhu Zhaoxu Chen Weiping Ding | 2018 | Science China Chemistry2018,61,8: | 0 |