|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Photonic cavity enhanced high-performance surface plasmon resonance biosensor显示文摘Herein we propose a novel strategy to enhance surface plasmon resonance(SPR)by introducing a photonic cavity into a total-internal-reflection architecture.The photonic cavity,which is comprised of a highly reflective photonic crystal(PC),defect layers,and a gold(Au)film,enables Fabry–Perot(FP)resonances in the defect layers and therefore narrows the SPR resonance width in the metallic surface as well as increases the electric field intensity and penetration depth in the evanescent region.The fabricated sensor exhibits a 5.7-fold increase in the figure of merit and a higher linear coefficient as compared with the conventional Au-SPR sensor.The demonstrated PC/FP cavity/metal structure presents a new design philosophy for SPR performance enhancement. | GUI-SHI LIU XIN XIONG SHIQI HU WEICHENG SHI YAOFEI CHEN WENGUO ZHU HUADAN ZHENG JIANHUI YU NUR HIDAYAH AZEMAN YUNHAN LUO ZHE CHEN | 2020 | Photonics Research2020,8,4: | 4 |
| 2 | High-performance fiber-integrated multifunctional graphene-optoelectronic device with photoelectric detection and optic-phase modulation显示文摘In graphene-based optoelectronic devices,the ultraweak interaction between a light and monolayer graphene leads to low optical absorption and low responsivity for the photodetectors and relative high half-wave voltage for the phase modulator.Here,an integration of the monolayer graphene onto the side-polished optical fiber is demonstrated,which is capable of providing a cost-effective strategy to enhance the light–graphene interaction,allowing us to obtain a highly efficient optical absorption in graphene and achieve multifunctions:photodetection and optical phase modulation.As a photodetector,the device has ultrahigh responsivity(1.5×10^(7) A/W)and high external quantum efficiency(>1.2×10^(9)%).Additionally,the polybutadiene/polymethyl methacrylate(PMMA)film on the graphene can render the device an optical phase modulator through the large thermo-optic effect of the PMMA.As a phase modulator,the device has a relatively low half-wave voltage of 3 V with a 16 dB extinction ratio in Mach–Zehnder interferometer configuration. | LINQING ZHUO PENGPENG FAN SHUANG ZHANG YUANSONG ZHAN YANMEI LINYU ZHANG DONGQUAN LI ZHEN CHE WENGUO ZHU HUADAN ZHENG JIEYUAN TANG JUN ZHANG YONGCHUN ZHONG WENXIAO FANG GUOGUANG LU JIANHUI YU ZHE CHEN | 2020 | Photonics Research2020,8,12: | 3 |
| 3 | Distance-controllable and direction-steerable opto-conveyor for targeting delivery显示文摘Opto-conveyors have attracted widespread interest in various fields because of their non-invasive and non-contact delivery of micro/nanoparticles.However,the flexible control of the delivery distance and the dynamic steering of the delivery direction,although very desirable in all-optical manipulation,have not yet been achieved by optoconveyors.Here,using a simple and cost-effective scheme of an elliptically focused laser beam obliquely irradiated on a substrate,a direction-steerable and distance-controllable opto-conveyor for the targeting delivery of microparticles is implemented.Theoretically,in the proposed scheme of the opto-conveyor,the transverse and longitudinal resultant forces of the optical gradient force and the optical scattering force result in the transverse confinement and the longitudinal transportation of microparticles,respectively.In this study,it is experimentally shown that the proposed opto-conveyor is capable of realizing the targeting delivery for microparticles.Additionally,the delivery distance of microparticles can be flexibly and precisely controlled by simply adjusting the irradiation time.By simply rotating the cylindrical lens,the proposed opto-conveyor is capable of steering the delivery direction flexibly within a large range of azimuthal angles,from-75°to 75°.This study also successfully demonstrated the real-time dynamic steering of the delivery direction from-45°to 45°with the dynamical rotation of the cylindrical lens.Owing to its simplicity,flexibility,and controllability,the proposed method is capable of creating new opportunities in bioassays as well as in drug delivery. | Zhen Che Wenguo Zhu Yaoming Huang Yu Zhang Linqing Zhuo Pengpeng Fan Zhibin Li Huadan Zheng Wenjin Long Wentao Qiu Yunhan Luo Jun Zhang Jinghua Ge Jianhui Yu Zhe Chen | 2020 | Photonics Research2020,8,7: | 1 |
| 4 | Optimized weak measurement of orbital angular momentum-induced beam shifts in optical reflection显示文摘Tiny but universal beam shifts occur when a polarized light beam is reflected upon a planar interface.Although the beam shifts of Gaussian beams have been measured by the weak measurement technique, the weak measurement for orbital angular momentum(OAM)-induced spatial shifts of vortex beams is still missing.Here, by elaborately choosing the preselection and postselection states, the tiny OAM-induced Goos–H?nchen and Imbert–Fedorov shifts are amplified at an air–prism interface. The maximum shifts along directions both parallel and perpendicular to the incident plane are theoretically predicted and experimentally verified with optimal preselection and postselection states. These maximum shifts can be used to determine the OAM of vortex beams. | Wenjin Long Jintao Pan Xinyi Guo Xiaohe Liu Haolin Lin Huadan Zheng Jianhui Yu Heyuan Guan Huihui Lu Yongchun Zhong Shenhe Fu Li Zhang Wenguo Zhu Zhe Chen | 2019 | Photonics Research2019,7,11: | 1 |
| 5 | High-sensitivity and fast-response fiber optic temperature sensor using an anti-resonant reflecting optical waveguide mechanism显示文摘Temperature sensing is essential for human health monitoring.High-sensitivity(>1 nm∕℃)fiber sensors always require long interference paths and temperature-sensitive materials,leading to a long sensor and thus slow response(6–14 s).To date,it is still challenging for a fiber optic temperature sensor to have an ultrafast(~ms)response simultaneously with high sensitivity.Here,a side-polished single-mode/hollow/single-mode fiber(SPSHSF)structure is proposed to meet the challenge by using the length-independent sensitivity of an anti-resonant reflecting optical waveguide mechanism.With a polydimethylsiloxane filled sub-nanoliter volume cavity in the SP-SHSF,the SP-SHSF exhibits a high temperature sensitivity of 4.223 nm/℃ with a compact length of 1.6 mm,allowing an ultrafast response(16 ms)and fast recovery time(176 ms).The figure of merit(FOM),defined as the absolute ratio of sensitivity to response time,is proposed to assess the comprehensive performance of the sensor.The FOM of the proposed sensor reaches up to 263.94(nm/℃)∕s,which is more than two to three orders of magnitude higher than those of other temperature fiber optic sensors reported previously.Additionally,a threemonth cycle test shows that the sensor is highly robust,with excellent reversibility and accuracy,allowing it to be incorporated with a wearable face mask for detecting temperature changes during human breathing.The high FOM and high stability of the proposed sensing fiber structure provide an excellent opportunity to develop both ultrafast and highly sensitive fiber optic sensors for wearable respiratory monitoring and contactless in vitro detection. | ZHIBIN LI ZIYE WU ZHUOQI LI LIANGXUN OU WENXIANG ZHANG ZHICONG LAI YU ZHANG MENGYUAN XIE JIEYUAN TANG WENGUO ZHU HUADAN ZHENG YONGCHUN ZHONG XIONG DENG XIHUA ZOU ZHE CHEN JIANHUI YU | 2023 | Photonics Research2023,11,8: | 0 |
| 6 | Side Polished Fiber:A Versatile Platform for Compact Fiber Devices and Sensors显示文摘Side polished fiber(SPF)has a controllable average roughness and length of the side-polishing region,which becomes a versatile platform for integrating multiple materials to interact with the evanescent field to fabricate all-fiber devices and sensors.It has been widely used in couplers,filters,polarizers,optical attenuators,photodetectors,modulators,and sensors for temperature,humidity,strain,biological molecules,chemical gas,and vector magnetic monitoring.In this article,an overview of the development history,fabrication techniques,fiber types,transmission characteristics,and varied recent applications of SPFs are reviewed.Firstly,the fabrication techniques of SPFs are reviewed,including the V-groove assisted polishing technique and wheel polishing technique.Then,the different types of SPFs and their characteristics are discussed.Finally,various applications of SPFs are discussed and concluded theoretically and experimentally,including their principles and structures.When designing the device,the residual thickness and polishing lengths of the SPF need to be appropriately selected in order to obtain the best performance.Developing all-fiber devices and sensors is aimed at practical usability under harsh environments and allows to avoid the high coupling loss between optical fibers and on-chip integrated devices. | Linqing ZHUO Jieyuan TANG Wenguo ZHU Huadan ZHENG Heyuan GUAN Huihui LU Yaofei CHEN Yunhan LUO Jun ZHANG Yongchun ZHONG Jianhui YU Zhe CHEN | 2023 | Photonic Sensors2023,13,1: | 0 |
| 7 | Pancreatic cancer with ovarian metastasis: cases report and literature review显示文摘Background: Pancreatic cancer with ovarian metastases is rare and easily misdiagnosed. Patients with ovarian metastases are first diagnosed with ovarian cancer and may miss the opportunity to receive surgical operation. We report 7 rare cases of ovarian metastases secondary to pancreatic adenocarcinoma and review the literature to analyze clinical characteristics, diagnostic methods, and potential therapeutic strategies for the rare malignancy.Cases Summary: We retrospectively analyzed the clinical data of 7 female patients with ovarian metastases of primary pancreatic cancer who were admitted to our hospital from January 01, 1985, to April 1, 2020. These 7 patients were diagnosed with ovarian metastasis at an average age of 52.28 (38-69) years. The reason for the patient’s visit was generally a mass in the lower abdomen and/or abdominal pain. Six of them had significantly higher serum Carbohydrate antigen19-9 (CA19-9) levels, 6 patients had pancreatic tumors located in the body or tail, and 1 patient had one in the head of the pancreas. All patients underwent excision of ovarian tumors and resection or biopsy of pancreatic tumors. Five patients had pancreatic ductal adenocarcinoma (PDAC), and 2 had pancreatic cystadenocarcinoma (PCC), all of which were revealed by the pathological results. Ovarian tumors were assessed by pathology and were consistent with pancreatic metastasis. Currently, all 7 patients have died (follow-up to January 2, 2021). The median survival time for all patients was 13.7 months (2.9-27 months).Conclusions: For this rare tumor, elevated serum CA19-9 may indicate that the primary lesion is in the pancreas. Enhanced pancreatic Computed Tomography (CT) can facilitate diagnostic localization. In addition, if the pancreatic tumor cannot be removed, the ovarian tumor should still be resected to reduce the tumor load and improve the quality of life. | Zeru Li Xingtong Zhou Bangbo Zhao Zhibo Zheng Cheng Qin Xudong Liu Huadan Xue Weibin Wang | 2023 | Journal of Pancreatology2023,6,1: | 0 |