维普中文期刊产品整合服务
1篇 您的检索式:作者名="Hkan Ahlstrm"
    题名 作者 年代 出处 被引量
1Comparison of different magnetic resonance imaging sequences for assessment of fistula-in-ano显示文摘AIM: To assess agreement between different forms of T2 weighted imaging(T2WI), and post-contrast T1WI in the depiction of fistula tracts, inflammation, and internal openings with that of a reference test. METHODS: Thirty-nine consecutive prospective cases were enrolled. The following sequences were used for T2WI: 2D turbo-spin-echo(2D T2 TSE); 3D T2 TSE; short tau inversion recovery(STIR); 2D T2 TSE with fat saturation performed in all patients. T1WI were either a 3D T1-weighted prepared gradient echo sequence with fat saturation or a 2D T1 fat saturation [Spectral presaturation with inversion(SPIR)]. Agreement for each sequence for determination of fistula extension, internal openings, and the presence of active inflammation was assessed separately and blindly against a reference test comprised of follow-up, surgery, endoscopic ultrasound, and assessment by an independent experienced radiologist with access to all images.RESULTS: Fifty-six fistula tracts were found: 2 intersphincteric, 13 trans-sphincteric, and 24 with additional tracts. The best T2 weighted sequence for depiction of fistula tracts was 2D T2 TSE(Cohen's kappa = 1.0), followed by 3D T2 TSE(0.88), T2 with fat saturation(0.54), and STIR(0.19). Internal openings were best seen on 2D T2 TSE(Cohen's kappa = 0.88), followed by 3D T2 TSE(0.70), T2 with fat saturation(0.54), and STIR(0.31). Detection of inflammation showed Cohen's kappa of 0.88 with 2D T2 TSE, 0.62 with 3D T2 TSE, 0.63 with STIR, and 0.54 with T2 with fat saturation. STIR, 3D T2 TSE, and T2 with fat saturation did not make any contributions compared to 2D T2 TSE. Post-contrast 3D T1 weighted prepared gradient echo sequence with fat saturation showed better agreement in the depiction of fistulae(Cohen's kappa = 0.94), finding internal openings(Cohen's kappa = 0.97), and evaluating inflammation(Cohen's kappa = 0.94) compared to post-contrast 2D T1 fat saturation or SPIR where the corresponding figures were 0.71, 0.66, and 0.87, respectively. Comparing the best T1 and T2 sequences showed that, for best results, both sequences were necessary. CONCLUSION: 3D T1 weighted sequences were best for the depiction of internal openings and active inflammatory components, while 2D T2 TSE provided the best assessment of fistula extension.Michael R Torkzad Hkan Ahlstrm Urban Karlbom 2014World Journal of Radiology2014,6,5:5
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费